<dl id="frz4o"><source id="frz4o"></source></dl>

  • 
    

      无码av一区二区|久久在线人人97|久久国产欧美日韩精品|国产AAA黄色片|国产精品午夜一区二区|亚洲AV无码专区在线播放麻豆|欧美一级人成a片免费观看|国产一级一看毛片

      single phase power supply lightning protection module HD-PMT1-35/260

      Online Inquiry
      Click Refresh Verification Code

      Details

      The HD-PMT1 is a Class I lightning surge protector for main power distribution systems. It has the advantages of strong lightning withstand capability up to 35KA (Iimp), low voltage protection level (≤ 2.5KV), extremely low failure rate, no leakage current, strong interrupted flow capability (25KA), and no electric arc leakage.It can be combined into 2P, 3P, 4P structure and is suitable for TT/TN/IT grid type. It is the best choice for lightning protection at the primary distribution panel, the main distribution cabinet, and the main switch.




      Model

      HD-PMT1-35/260

      Number of modules

      2

      3

      4

      Suitable power grid type

      TT/TN-S/TN-C-S

      TN-C-IT

      TT/TN-S/TN-C-S

      Nominal voltage Un

      220V

      Maximum continuous working voltage Uc

      260V

      Voltage protection level Up

      2.5KV

      Maximum discharging current Imax8/20μs

      100KA

      Impact current Iimp

      35KA

      Short-circuit withstand current

      25KA

      Response time Ta

      100ns

      Pre-fuse

      125A

      Leakage current

      <5uA

      Connecting wire diameter

      6mm2

      Operating temperature

      -40 to +70

      Humidity

      95%

      Altitude

      2000m

      Protection degree

      IP20

      Flame retardant level UL94

      V0

      Installation

      Clip on 35mm electrical guideway

      Protection mode

      L/N-PE

      3L-N/PE3L-PE

      3L/N-PE

      External dimension

      72*90*65mm

      108*90*65mm

      144*90*65mm


      Ground the null line repeatedly when Long-distance overhead incoming lines enter buildings.

      Plug the power phase line (L) and null line (Ninto corresponding connector of the electric surge protector and make sure it's firm and reliable. Connect the ground terminal of arrester with the ground lead of lightning protection well (recommended earth resistance 4Ω).

      Suggested specification of the lead wire: no less than 6mm2, short and straight.