      Power distribution lightning protection module HD-PMT2

      Online Inquiry
      Click Refresh Verification Code

      Details

      HD-PMT2 is a Class II lightning surge protector applied to the main distribution system. It has the advantages of strong lightning withstand capability up to 40KA (Imax), low voltage protection level (≤1.7KV), leakage current less than 10uA, and intermittent flow capability (25KA). With integrated base and pluggable chip structure, there are 2P, 4P combination, suitable for TT/TN grid type. It is the best choice for distributing secondary lightning protection at the cabinet and secondary switch.




      Model

      HD-PMT2-40/385

      HD-PMT2-20/385

      Number of modules

      4P/2P

      4P/2P

      Suitable power grid type

      TT/TN-S/TN-C-S

      TT/TN-S/TN-C-S

      Nominal voltage Un

      220/380V

      220V/380V

      Maximum continuous working voltage Uc

      385V

      385V

      Voltage protection level Up

      1.7KV

      1.6KV

      Nominal discharging current In

      20KA

      10KA

      Maximun discharging current Imax

      40KA

      20KA

      Response time Ta

      25ns

      25ns

      Pre-fuse

      32A

      16A

      Leakage current

      10uA

      Connecting wire diameter

      6mm2

      Fault indication

      Yes

      Operating temperature

      -40~+70

      Humidity

      95%

      Altitude

      2000m

      Protection degree

      IP20

      Flame retardant level

      V0

      Installation

      Clip on 35mm electrical guideway

      Protection mode

      L/N-PEL-N-PE

      3L/N-PE3L-N-PE

      External dimension

      72*90*65mm/36*90*65mm


      Ground the null line repeatedly when Long-distance overhead incoming lines enter buildings.

      Plug the power phase line (L) and null line (Ninto corresponding connector of the electric surge protector and make sure it's firm and reliable. Connect the ground terminal of arrester with the ground lead of lightning protection well (recommended earth resistance 4Ω).

      Suggested specification of the lead wire: no less than 6mm2, short and straight.