      Cabinet type explosion proof power supply lightning protection boxsmall


      Performance Instruction:

      Electric surge protector of low-voltage distribution system, which is in the form of a box, is explosion proof and designed according to IEC standard. It has invalidation detection indication, overflowing and overheating protection, and powerful discharge capacity of lightning current. It's applicable to the protection of buildings' general supply system against lightning. This lightning arrester is very convenient to be maintained. It connects with the circuit in parallel and has no limit to the power of equipment fixed later.


      Model

      HD-D380(220)B-XSF60

      HD-D380(220)C-XSF40

      HD-D380(220)C-XSF20

      HD-D380/220C-XSF

      Nominal working voltage Un

      380V/220V

      380V/220V

      380V/220V

      380V/220V

      Maximum continuous working voltage Uc

      385V/275V

      385V/275V

      385V/275V

      385V/275V

      Nominal discharge currentIn8/20ms

       30KA

      20KA

      10KA

      20KA

      Maximum discharging currentImax8/20ms

       60KA

      40KA

      20KA

      40KA

      Voltagprotection level Up

      2KV

      1.6KV

      1.2V

      2.1KV

      Prepositive overflowing protection

      63A

      32A

      16A

      32A

      Overall dimension

      260×180×85mm

      Response time Ta

      25ns

      Operating temperature range Tup

      -40℃至+70℃

      Working order indication

      Green light means normal working, red light is fault indication.

      Section of minimum installed conductor

      6m2 Multi-folded wire

      Explosion proof function

      Available

      Protection grade

      IP20

      Sheathing material

      Mellozing

      Mode of connection

      Parallel connection

      Protection mode

      4+0/3+1/1+1/2+0


      Installation Method:

      Ground the null line repeatedly when long-distance overhead incoming feeder is connected to the building.
      Plug the power phase line (L) and null line (Ninto corresponding connector of the electric surge protector and make sure it's firm and reliableand connect the ground terminal of arrester with the ground lead of lightning protection appropriately (recommended earth resistance ≤4Ω).
      Suggested specification of the lead wire: no less than 10m2, short and straight.