      Power supply lightning protection module(B+C type)

      Online Inquiry
      Click Refresh Verification Code

      Details

      Power supply lightning protection moduleB+C type


      Electric surge protector of composite low-voltage distribution system is designed according to IEC standard. It adopts the most advanced technology of pre-ignition clearance and automatic matching of energy and has invalidation detection indication, standard modularization installation, and powerful discharge capacity of lightning current. It's applicable to the protection of buildings' general supply system against lightning.With 35mm standard guide-way, this lightning arrester is very convenient to be maintained. It connects with the circuit in parallel and has no limit to the power of equipment fixed later.





      Model

      HD-D380(220)BCM160

      HD-D380(220)BCM100

      HD-D380(220)BCM80

      HD-D380(220)BCM60

      Nominal working voltage Un

      380V/220V

      380V/220V

      380V/220V

      380V/220V

      Maximum continuous working voltage Uc

      385V/275V

      385V/275V

      385V/275V

      385V/275V

      Nominal discharge current In8/20ms

      80KA

      50KA

      40KA

      30KA

      Maximum discharging current Imax8/20ms

      160KA

      100KA

      80KA

      60KA

      Voltage protection level Up

      2.7KV

      2KV

      1.8KV

      1.5KV

      Overall dimension

      197×90×64mm

      Response time Ta

      25ns

      Operating temperature range Tup

      -40℃至+80

      Section of minimum installed conductor

      6mm2 Multi-folded wire

      Protection grade

      IP20

      Sheathing material

      Flame retardant thermoplastic material

      Mode of connection

      Parallel connection

      Installation Method:

      Ground the null line repeatedly when long-distance overhead incoming feeder is connected to the building.
      Plug the power phase line (L) and null line (Ninto corresponding connector of the electric surge protector and make sure it's firm and reliable. Connect the ground terminal of arrester with the ground lead of lightning protection appropriately (recommended earth resistance ≤4Ω).

      Suggested specification of the lead wire: no less than 6mm2, short and straight.