      HD-BUPS

      Online Inquiry
      Click Refresh Verification Code

      Details

      Dedicated lightning protection box for compotator UPS


      This product is applicable to lightning and electric surge protection of lightning protection area LPZ1 or LPZ2 to LPZ3 area (Grade D or Grade ), as well as single-phase and three-phase supply circuit. Vital components of this product adopt the advanced high capacity surge absorber member MOVand have passed the burn-in screen with even quality and quick response time. Product connection in series is superior to that of parallel connection in protective property. It has even lower limit to output voltage and can protect the equipment effectively. With LC filter circuit and current limiting device, its protection grade can reach IP30. This kind of product is of complete function, convenient installation, and the function of operating light as well as fault detection.



      Model

      HD-BUPS8/10

      HD-BUPS6/7

      HD-BUPS6/5

      HD-CUPS4/4

      HD-CUPS2/2

      Nominal working voltage Un

      220V

      220V

      220V

      220V

      220V

      Maximum continuous working voltage Uc

      275V

      275V

      275V

      275V

      275V

      Nominal discharge current In8/20ms

      40KA

      30KA

      30KA

      20KA

      10KA

      Maximum discharging current Imax8/20ms

      80KA

      60KA

      60KA

      40KA

      20KA

      Voltage protection level Up

      2.4KV

      1.6KV

      1.6KV

      1.2KV

      0.8KV

      Prepositive overflowing protection

      63A

      63A

      32A

      32A

      32A

      Power

      10KW

      7KW

      5KW

      4KW

      2KW

      External dimension

      360×250×230mm

      Response time Ta

      25ns

      Operating temperature range Tup

      -40℃至+70

      Working order indication

      Green light means normal working, red light is fault indication.

      Section of minimum installed conductor

      6mm2 Multi-folded wire

      Sheathing material

      Metal Spraying

      Mode of connection

      Connection in series

      Protection mode

      Overall protection


      Installation Method: Ground the null line repeatedly when long-distance overhead incoming feeder is connected to the building. L and N are terminal for power incoming feeder; L ' and N ' are terminal for lead-in equipment, which is installed at the leading end of DPS incoming feeder. It's suggested power earthing (PE) be well connected with lightning protection ground lead (suggested earth resistance ≤4Ω).Suggested specification of the lead wire: no less than 10m2, short and straight.