      Cabinet type power supply lightning arrester(big)

      Online Inquiry
      Click Refresh Verification Code

      Details

      Electric surge protector of low-voltage distribution system, which is in the form of a box, is designed according to IEC standard.It has invalidation detection indication, lightning stroke numbering display,installed overflowing and overheating protection with great lightning current discharge capability. It's applicable to the protection of buildings' general supply system against lightning, as well as Grade 1 and 2 lightning protection of the general supply in building, machine room, plant and enterprise to make sure the safe operation of electronic equipment and other electrical equipment. This lightning arrester is very convenient to be maintained. It connects with the circuit in parallel and has no limit to the power of equipment fixed later.



      Model

      HD-D380B-XL160

      HD-D380B-XL100

      HD-D380B-XL80

      HD-D380B-XL60

      Nominal working voltage Un

      380V

      380V

      380V

      380V

      Maximum continuous working voltage Uc

      385V

      385V

      385V

      385V

      Nominal discharge current In 8/20μs

      80KA

      50KA

      40KA

      30KA

      Maximum discharging current Imax8/20μs

      160KA

      100KA

      80KA

      60KA

      Voltage protection level Up

      3.5KV

      2.5KV

      2.3KV

      2KV

      Prepositive overflowing protection

      125A

      125A

      125A

      63A

      Response time Ta

      25ns

      Operating temperature range Tup

      -40to+70

      Working condition indication

      Green light means work normally,red light means fault indicaiton.

      Section of minimum installed conductor

      6mm2 multi-folded wire

      Protection grade

      IP20

      External dimension

      300*400*130mm

      Sheathing material

      Metal spraying

      Mode of connection

      parallel connection

      Protection mode

      4+0/3+1/1+1/2+0

























      Installation method:


      Ground the null line repeatedly when Long-distance overhead incoming lines enter buildings.

      Plug the power phase line (L) and null line (Ninto corresponding connector of the electric surge protector and make sure it's firm and reliable. Connect the ground terminal of arrester with the ground lead of lightning protection well (recommended earth resistance 4Ω).

      Suggested specification of the lead wire: no less than 6mm2, short and straight.