      Explosion-proof lightning protection box HD-D380/220C-XSF

      Online Inquiry
      Click Refresh Verification Code

      Details

      Crate-type explosion-proof power supply lightning protection box

      Electric surge protector of low-voltage distribution system, which is in the form of a box, is explosion proof and designed according to IEC standard. It has invalidation detection indication, overflowing and overheating protection with powerful discharge capacity of lightning current. It's applicable to the protection of buildings' general supply system against lightning. It is very convenient to be maintained. It connects with the circuit in parallel and has no limit to the power of equipment fixed later.


      Model

       

      HD-D380(220)B-XSF60

       

      HD-D380(220)C-XSF40

       

      HD-D380(220)C-XSF20

       

      HD-D380/220C-XSF

      Nominal working voltage Un

       

      380V/220V

       

      380V/220V

       

      380V/220V

       

      380V/220V

      Maximum continuous working voltage Uc

       

      385V/275V

       

      385V/275V

       

      385V/275V

       

      385V/275V

      Nominal discharge currentIn8/20ms

      30KA

       

      20KA

       

      10KA

       

      20KA

      Maximum discharging currentImax8/20ms

      60KA

       

      40KA

       

      20KA

       

      40KA

      Voltagprotection level Up

      2KV

      1.6KV

       

      1.2V

       

      2.1KV

      Prepositive overflowing protection

      63A

       

      32A

       

      16A

       

      32A

      Overall dimension

       

      260×180×85mm

      Response time Ta

       

      25ns

      Operating temperature range Tup

       

      -40℃至+70

      Working order indication

      Green light means normal working, red light is fault indication.

      Section of minimum installed conductor

      6m2 Multi-folded wire

      Explosion proof function

      Available

      Protection grade

      IP20

      Sheathing material

      Metal spraying

      Mode of connection

      Parallel connection

      Protection mode

      4+0/3+1/1+1/2+0


      Ground the null line repeatedly when Long-distance overhead incoming lines enter buildings.

      Plug the power phase line (L) and null line (Ninto corresponding connector of the electric surge protector and make sure it's firm and reliable. Connect the ground terminal of arrester with the ground lead of lightning protection well (recommended earth resistance 4Ω).

      Suggested specification of the lead wire: no less than 6mm2, short and straight.